1.
3D Print Med ; 10(1): 12, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38627256

RESUMO

BACKGROUND: Device-related bacterial infections account for a large proportion of hospital-acquired infections. The ability of bacteria to form a biofilm as a protective shield usually makes treatment impossible without removal of the implant. Topographic surfaces have attracted considerable attention in studies seeking antibacterial properties without the need for additional antimicrobial substances. As there are still no valid rules for the design of antibacterial microstructured surfaces, a fast, reproducible production technique with good resolution is required to produce test surfaces and to examine their effectiveness with regard to their antibacterial properties. METHODS: In this work various surfaces, flat and with microcylinders in different dimensions (flat, 1, 3 and 9 µm) with a surface area of 7 × 7 mm were fabricated with a nanoprinter using two-photon lithography and evaluated for their antibiofilm effect. The microstructured surfaces were cultured for 24 h with different strains of Pseudomonas aeruginosa and Staphylococcus aureus to study bacterial attachment to the patterned surfaces. In addition, surface wettability was measured by a static contact angle measurement. RESULTS: Contact angles increased with cylinder size and thus hydrophobicity. Despite the difference in wettability, Staphylococcus aureus was not affected by the microstructures, while for Pseudomonas aeruginosa the bacterial load increased with the size of the cylinders, and compared to a flat surface, a reduction in bacteria was observed for one strain on the smallest cylinders. CONCLUSIONS: Two-photon lithography allowed rapid and flexible production of microcylinders of different sizes, which affected surface wettability and bacterial load, however, depending on bacterial type and strain.

2.
ASAIO J ; 70(4): 249-256, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38081043

RESUMO

Driveline infection (DLI) is associated with increased mortality and morbidity in left ventricular assist device (LVAD) patients. Because trauma to the driveline exit-site (DLES) is a risk factor for DLI, adhesive anchoring devices are used to immobilize the DL. In this study, commonly used products (identified through literature review and contact with nine international VAD implantation centers) were mechanically characterized to evaluate their effectiveness in preventing DLES trauma. Eight devices were tested in an in vitro abdominal model of the DLES, where a tensile force (10 N) was applied to a HeartMate 3 DL, whereas the resulting force ( FTotal ) on the DLES was recorded using a three-axis load cell. Four devices (CathGrip: FTotal = 2.1 ± 0.4 N, Secutape: FTotal = 2.6 ± 0.3 N, Hollister: FTotal = 2.7 ± 0.5 N, Tubimed: FTotal = 2.9 ± 0.2 N) were significantly ( p < 0.05) better at preventing tensile forces at the DLES compared to the other four devices (Main-Lock: FTotal = 3.7 [0.7] N, Secutape sensitive: FTotal = 3.9 ± 0.4 N, Foley Anchor: FTotal = 4.3 ± 0.5 N, Grip-Lok: FTotal = 5.4 ± 0.8 N). Immobilization of the DL with each anchoring device resulted in lower tensile force on the DLES than without an anchor ( FTotal = 8.2 ± 0.3 N). In conclusion, the appropriate selection of anchoring devices plays a critical role in reducing the risk of DLI, whereas the CathGrip, Secutape, Hollister, or Tubimed were superior in preventing trauma to the DLES in this study.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Infecções Relacionadas à Prótese , Humanos , Coração Auxiliar/efeitos adversos , Infecções Relacionadas à Prótese/prevenção & controle , Infecções Relacionadas à Prótese/etiologia , Estudos Retrospectivos , Fatores de Risco , Insuficiência Cardíaca/complicações
3.
J Heart Lung Transplant ; 43(2): 251-260, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37769887

RESUMO

PURPOSE: The HeartMate 3 (HM3) left ventricular assist device (LVAD) has demonstrated excellent clinical outcomes; however, pump speed optimization is challenging with the available HM3 monitoring. Therefore, this study reports on clinical HM3 parameters collected with a noninvasive HM3 monitoring system (HM3 Snoopy) during echocardiographic speed ramp tests and Valsalva maneuvers. METHODS: In this prospective, single-center study, the HM3 data communication between the controller and pump was recorded with a novel data acquisition system. Twelve pump parameters sampled every second (1 Hz) and clinical assessments (echocardiography, electrocardiogram (ECG), and blood pressure measurement) during speed ramp tests were analyzed using Pearson's correlation (r, median [IQR]). The cause for the occurrence of pulsatility index (PI)-events during ramp speed tests and valsalva maneuvers was investigated. RESULTS: In 24 patients (age: 58.9 ± 8.8 years, body mass index: 28.1 ± 5.1 kg/m2, female: 20.8%), 35 speed ramp tests were performed with speed changes in the range of ±1000 rpm from a baseline speed of 5443 ± 244 rpm. Eight HM3 pump parameters from estimated flow, motor current, and LVAD speed together with blood pressure showed positive collinearities (r = 0.9 [0.1]). Negative collinearities were observed for pump flow pulsatility, pulsatility index, rotor noise, and left ventricular diameters (r = -0.8 [0.1]), whereas rotor displacement and heartrate showed absence of collinearities (r = -0.1 [0.08]). CONCLUSIONS: In this study, the HM3 Snoopy was successfully used to acquire more parameters from the HM3 at a higher sampling rate. Analysis of HM3 per-second data provide additional clinical diagnostic information on heart-pump interactions and cause of PI-events.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Manobra de Valsalva , Ecocardiografia , Coração Auxiliar/efeitos adversos
4.
Adv Healthc Mater ; 12(23): e2300520, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37173073

RESUMO

Clinically available small-diameter synthetic vascular grafts (SDVGs) have unsatisfactory patency rates due to impaired graft healing. Therefore, autologous implants are still the gold standard for small vessel replacement. Bioresorbable SDVGs may be an alternative, but many polymers have inadequate biomechanical properties that lead to graft failure. To overcome these limitations, a new biodegradable SDVG is developed to ensure safe use until adequate new tissue is formed. SDVGs are electrospun using a polymer blend composed of thermoplastic polyurethane (TPU) and a new self-reinforcing TP(U-urea) (TPUU). Biocompatibility is tested in vitro by cell seeding and hemocompatibility tests. In vivo performance is evaluated in rats over a period for up to six months. Autologous rat aortic implants serve as a control group. Scanning electron microscopy, micro-computed tomography (µCT), histology, and gene expression analyses are applied. TPU/TPUU grafts show significant improvement of biomechanical properties after water incubation and exhibit excellent cyto- and hemocompatibility. All grafts remain patent, and biomechanical properties are sufficient despite wall thinning. No inflammation, aneurysms, intimal hyperplasia, or thrombus formation are observed. Evaluation of graft healing shows similar gene expression profiles of TPU/TPUU and autologous conduits. These new biodegradable, self-reinforcing SDVGs may be promising candidates for clinical use in the future.


Assuntos
Engenharia Tecidual , Enxerto Vascular , Ratos , Animais , Microtomografia por Raio-X , Prótese Vascular , Poliuretanos
5.
J Med Syst ; 47(1): 58, 2023 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-37133553

RESUMO

BACKGROUND: Despite recent design improvements, human factors issues continue to challenge left ventricular assist device (LVAD) therapy. The aim of this study was to evaluate user experience of former non-HeartMate 3 (HM3) LVAD patients post heart transplantation (HTX) and laypersons (LP) with HM3 LVAD peripherals in simulated everyday and emergency scenarios. METHODS: This single center cohort study included untrained HTX and LP. Seven scenarios, including battery exchanges (without alarm, advisory alarm, dim light, consolidated bag), change of power supply, driveline dis-/reconnection and controller exchange were simulated. Subjects' gaze behavior was recorded using eye tracking technology. Success rate, pump-off-time, duration to success (DTS), percental fixation duration per areas of interest and post-scenario-survey results were defined as outcome measures. RESULTS: Thirty subjects completed 210 scenarios, initially solving 82.4% (HTX vs. LP, p = 1.00). Changing power supply revealed highest complexity (DTS = 251 ± 93s, p = 0.76): 26.7% succeeded at first attempt (p = 0.68), 56.7% at second attempt, with significantly more LP failing (p = 0.04), resulting in 10 hazards from driveline disconnections (pump-off-time 2-118s, p = 0.25). Comparison on initial success showed differences in fixation durations for seven areas of interest (p < 0.037). Decreasing DTS during battery exchanges (p < 0.001) indicate high learnability. Exchanging batteries within the bag took longer (median DTS = 75.0 (IQR = 45.0)s, p = 0.09), especially in elderly subjects (r = 0.61, p < 0.001). Subjects with less initial success were more afraid of making mistakes (p = 0.048). CONCLUSION: This eye tracking based human factors study provided insights into user experiences in handling HM3 peripherals. It highlights unintuitive and hazardous characteristics, providing guidance for future user-centered design of LVAD wearables.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Humanos , Idoso , Insuficiência Cardíaca/cirurgia , Tecnologia de Rastreamento Ocular , Estudos de Coortes , Estudos Retrospectivos
6.
J Cardiopulm Rehabil Prev ; 43(5): 346-353, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37014949

RESUMO

PURPOSE: Exercise performance and quality of life (QoL) of left ventricular assist device (LVAD) patients improve after early cardiac rehabilitation (CR). The purpose of this study was to examine the efficacy of multiprofessional long term phase 3 outpatient CR, and whether cardiopulmonary exercise testing (CPX) and 6-min walk testing (6MWT) post-LVAD implantation predict hospital readmission. METHODS: This retrospective observational cohort study included 29 LVAD patients (58.6 ± 7.7 yr, female: 13.8%, body mass index: 29.4 ± 3.3 kg/m 2 ). Functional performance tests (CPX, 6MWT, sit-to-stand test), QoL, and psychological surveys (Kansas City Cardiomyopathy Questionnaire, hospital anxiety and depression scale, and Control Convictions about Disease and Health [KKG]) were performed at baseline and at the end of CR. RESULTS: The CR was initiated at a median (IQR) of 159 (130-260) d after LVAD implantation for a duration of 340 (180-363) d with 46.8 ± 23.2 trainings. The 6MWT (408.4 ± 113.3 vs 455.4 ± 115.5 m, P = .003) and sit-to-stand test (16.7 ± 6.9 vs 19.0 ± 5.3 repetitions, P = .033) improved, but relative peak oxygen uptake (V˙ o2peak : 9.4 [8.2-14.4] vs 9.3 [7.8-13.4] mL/min/kg, P = .57) did not change. Using receiver operating characteristic curve analysis, baseline V˙ o2peak values were associated with readmission 1-yr after CR onset (C-statistic = 0.88) with a cutoff value of V˙ o2peak < 9.15 mL/min/kg (100% sensitivity, 78% specificity, P < .001). The Kansas City Cardiomyopathy Questionnaire self-efficacy and knowledge (+6.3 points), QoL (+5.0 points), and social limitation (+7.1 points) demonstrated clinically important changes. In addition, the hospital anxiety and depression scale showed a significant reduction in anxiety (4.6 ± 3.2 vs 2.6 ± 2.4, P = .03). CONCLUSIONS: Long-term CR is safe and LVAD outpatients showed improvement of QoL, anxiety, and submaximal exercise performance. In addition, V˙ o2peak and 6MWT have prognostic value for readmission.


Assuntos
Reabilitação Cardíaca , Cardiomiopatias , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Feminino , Qualidade de Vida , Pacientes Ambulatoriais , Estudos Retrospectivos
7.
ASAIO J ; 69(6): 595-601, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36821448

RESUMO

VISUAL ABSTRACT: of key results. INR, international normalized ratio; TTR, time in therapeutic range; PTR, percentage of tests in range; HRAE, hemocompatibility-related adverse event; FFUV, first follow-up visit; GIB, gastrointestinal bleeding; HR, hazard ratio.http://links.lww.com/ASAIO/A961.


Assuntos
Coração Auxiliar , Varfarina , Humanos , Anticoagulantes/efeitos adversos , Coagulação Sanguínea , Coeficiente Internacional Normatizado/métodos , Femprocumona/efeitos adversos , Varfarina/efeitos adversos
8.
J Heart Lung Transplant ; 42(4): 466-477, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36682893

RESUMO

BACKGROUND: Despite design improvements in left ventricular assist devices (LVADs) over the past decade, limitations of external, wearable VAD components affect patient quality of life and safety. The aim of this study was to describe both user experience and human factor issues of 2 contemporary LVADs. METHODS: This single-center, cross-sectional study included LVAD outpatients who were at least 3 months after implantation. Before developing the 16-item survey, a systematic literature review and 2-round Delphi method involving 9 VAD clinicians were used to select items in 6 domains: power supply, emergency situations, wearability, mobility, and freedom to travel, user modifications, lifestyle, and home adaptations. RESULTS: Fifty-eight patients (61.6 ± 11.6 years, 13.8% female, HeartMate 3 (HM3)/HVAD: n = 39/19) completed the one-time survey after median of 853 days on device: 10.3% reported problems changing power supply, 12.7% unintentional driveline disconnection (HM3: 5.6% vs HVAD: 26.3%, p = 0.041). Against the recommendation 74.1% sleep with battery-support (HM3: 88.9% vs HVAD: 44.4%, p = 0.001). About 65.3% criticized the carry bag weight/size (HM3: 71.4% vs HVAD: 50.0%, p = 0.035), thus 24.1% wear an own carrying-system, 42.1% modified their wearables, 38.9% their clothing, and 65.3% their home to cope with life on LVAD support. Mobility is reduced due to limited wearability: 18.9% went abroad (only 3.7% by plane) and 40.0% use less public transport than before implantation (the older the less: r = -0.37, p = 0.013). CONCLUSIONS: HVAD and HM3 wearables still show a variety of human factors issues and potential for improved user experience. User-centered design and incorporation of patient feedback may increase user satisfaction, and patient safety.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Dispositivos Eletrônicos Vestíveis , Feminino , Humanos , Masculino , Estudos Transversais , Insuficiência Cardíaca/cirurgia , Qualidade de Vida , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Fatores de Risco
9.
Front Physiol ; 13: 1010862, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36246102

RESUMO

Atrial fibrillation (AF) is a common comorbidity in left ventricular assist device (LVAD) patients and has been identified as a risk factor for thromboembolic stroke. Blood stagnation within the left atrial appendage (LAA) is considered a possible major source of thrombosis and clinical studies have shown reduced thromboembolic risk after LAA occlusion (LAAO). Therefore, this study aims to investigate the effect of LAAO on thrombosis-related parameters using patient-specific simulations. Left ventricular and left atrial geometries of an LVAD patient were obtained from computed tomography and combined with hemodynamic data with either sinus rhythm (SR) or AF generated by a lumped parameter model. In four simulations applying contractile walls, stagnation volume and blood residence times were evaluated with or without AF and with or without LAAO. Reduced atrial contraction in AF resulted in unfavorable flow dynamics within the left atrium. The average atrial velocity was lower for the AF simulation when compared to SR, resulting in a 55% increase in the atrial stagnation volume (from 4.2 to 6.5 cm3). Moreover, blood remained in the LAA for more than 8 cardiac cycles. After LAAO the atrial stagnation decreased from 4.2 to 1.4 cm3 for SR and from 6.5 to 2.3 cm3 for the AF simulation. A significant stagnation volume was found in the LAA for both SR and AF, with larger values occurring with AF. These regions are known as potential sources for thrombus formation and can be diminished by LAAO. This significantly improved the thrombus-related flow parameters and may also lower the risk of thromboembolic events from the appendage.

10.
Front Cardiovasc Med ; 9: 888269, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35548436

RESUMO

Background: Contemporary Left Ventricular Assist Devices (LVADs) mainly operate at a constant speed, only insufficiently adapting to changes in patient demand. Automatic physiological speed control promises tighter integration of the LVAD into patient physiology, increasing the level of support during activity and decreasing support when it is excessive. Methods: A sensorless modular control algorithm was developed for a centrifugal LVAD (HVAD, Medtronic plc, MN, USA). It consists of a heart rate-, a pulsatility-, a suction reaction-and a supervisor module. These modules were embedded into a safe testing environment and investigated in a single-center, blinded, crossover, clinical pilot trial (clinicaltrials.gov, NCT04786236). Patients completed a protocol consisting of orthostatic changes, Valsalva maneuver and submaximal bicycle ergometry in constant speed and physiological control mode in randomized sequence. Endpoints for the study were reduction of suction burden, adequate pump speed and flowrate adaptations of the control algorithm for each protocol item and no necessity for intervention via the hardware safety systems. Results: A total of six patients (median age 53.5, 100% male) completed 13 tests in the intermediate care unit or in an outpatient setting, without necessity for intervention during control mode operation. Physiological control reduced speed and flowrate during patient rest, in sitting by a median of -75 [Interquartile Range (IQR): -137, 65] rpm and in supine position by -130 [-150, 30] rpm, thereby reducing suction burden in scenarios prone to overpumping in most tests [0 [-10, 2] Suction events/minute] in orthostatic upwards transitions and by -2 [-6, 0] Suction events/min in Valsalva maneuver. During submaximal ergometry speed was increased by 86 [31, 193] rpm compared to constant speed for a median flow increase of 0.2 [0.1, 0.8] L/min. In 3 tests speed could not be increased above constant set speed due to recurring suction and in 3 tests speed could be increased by up to 500 rpm with a pump flowrate increase of up to 0.9 L/min. Conclusion: In this pilot study, safety, short-term efficacy, and physiological responsiveness of a sensorless automated speed control system for a centrifugal LVAD was established. Long term studies are needed to show improved clinical outcomes. Clinical Trial Registration: ClinicalTrials.gov, identifier: NCT04786236.

11.
Life (Basel) ; 12(4)2022 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-35455054

RESUMO

Advanced stage heart failure patients can benefit from the unloading effects of an implantable left ventricular assist device. Despite best clinical practice, LVADs are associated with adverse events, such as pump thrombosis (PT). An adaptive algorithm alerting when an individual's appropriate levels in pump power uptake are exceeded, such as in the case of PT, can improve therapy of patients implanted with a centrifugal LVAD. We retrospectively studied 75 patients implanted with a centrifugal LVAD in a single center. A previously optimized adaptive pump power-tracking algorithm was compared to clinical best practice and clinically available constant threshold algorithms. Algorithm performances were analyzed in a PT group (n = 16 patients with 30 PT events) and a thoroughly selected control group (n = 59 patients, 34.7 patient years of LVAD data). Comparison of the adaptive power-tracking algorithm with the best performing constant threshold algorithm resulted in sensitivity of 83.3% vs. 86.7% and specificity of 98.9% vs. 95.3%, respectively. The power-tracking algorithm produced one false positive detection every 11.6 patient years and early warnings with a median of 3.6 days prior to PT diagnosis. In conclusion, a retrospective single-center validation study with real-world patient data demonstrated advantageous application of a power-tracking algorithm into LVAD systems and clinical practice.

12.
Life (Basel) ; 12(3)2022 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-35330210

RESUMO

Right heart failure (RHF) is a severe complication after left ventricular assist device (LVAD) implantation. The aim of this study was to analyze the incidence, risk factors, and biomarkers for late RHF including the possible superiority of the device and implantation method. This retrospective, single-center study included patients who underwent LVAD implantation between 2014 and 2018. Primary outcome was freedom from RHF over one-year after LVAD implantation; secondary outcomes included pre- and postoperative risk factors and biomarkers for RHF. Of the 145 consecutive patients (HeartMate 3/HVAD: n = 70/75; female: 13.8%), thirty-one patients (21.4%) suffered RHF after a mean LVAD support of median (IQR) 105 (118) days. LVAD implantation method (less invasive: 46.7% vs. 35.1%, p = 0.29) did not differ significantly in patients with or without RHF, whereas the incidence of RHF was lower in HeartMate 3 vs. HVAD patients (12.9% vs. 29.3%, p = 0.016). Multivariate Cox proportional hazard analysis identified HVAD (HR 4.61, 95% CI 1.12-18.98; p = 0.03), early post-op heart rate (HR 0.96, 95% CI 0.93-0.99; p = 0.02), and central venous pressure (CVP) (HR 1.21, 95% CI 1.05-1.39; p = 0.01) as independent risk factors for RHF, but no association of RHF with increased all-cause mortality (HR 1.00, 95% CI 0.99-1.01; p = 0.50) was found. To conclude, HVAD use, lower heart rate, and higher CVP early post-op were independent risk factors for RHF following LVAD implantation.

13.
Artif Organs ; 46(6): 1149-1157, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34978722

RESUMO

BACKGROUND: A relation between the left ventricular assist device inflow cannula (IC) malposition and pump thrombus has been reported. This study aimed to investigate if the pump position, derived from chest X-rays in HeartMate 3 (HM3) patients, correlates with neurological dysfunction (ND), ischemic stroke (IS), hemorrhagic stroke (HS) and survival. METHODS: This analysis was performed on routinely acquired X-rays of 42 patients implanted with a HM3 between 2014 and 2017. Device position was quantified in patients with and without ND from frontal and lateral X-rays characterizing the IC and pump in relation to spine, diaphragm or horizontal line. The primary end-point was freedom from stroke and survival one-year after HM3 implantation stratified by pump position. RESULTS: The analysis of X-rays, 33.5 (41.0) days postoperative, revealed a significant smaller IC angle of HM3 patients with ND versus no ND (0.1° ± 14.0° vs. 12.9° ± 10.1°, p = 0.005). Additionally, the IC angle in the frontal view, IS: 4.1 (20.9)° versus no IS: 13.8 (7.5)°, p = 0.004 was significantly smaller for HM3 patients with IS. Using receiver operating characteristics derived cut-off, IC angle <10° provided 75% sensitivity and 100% specificity (C-statistic = 0.85) for predicting IS. Stratified by IC angle, freedom from IS at 12 months was 100% (>10°) and 60% (<10°) respectively (p = 0.002). No significant differences were found in any end-point between patients with and without HS. One-year survival was significantly higher in patients with IC angle >10° versus <10° (100% vs. 71.8%, p = 0.012). CONCLUSIONS: IC malposition derived from standard chest X-rays serves as a risk factor for ND, IS and worse survival in HM3 patients.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Trombose , Cânula/efeitos adversos , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/complicações , Trombose/etiologia
14.
Int J Artif Organs ; 45(4): 421-430, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34715752

RESUMO

Simulations of the ventricular flow patterns during left ventricular assist device (LVAD) support are mainly performed with idealized cylindrical inflow, neglecting the influence of the atrial vortex. In this study, the influence of the left atrium (LA) on the intra-ventricular flow was investigated via Computational Fluid Dynamics (CFD) simulations. Ventricular flow was simulated by a combined Eulerian (carrier flow)/Lagrangian (particles) approach taking into account either the LA or a cylindrical inflow section to mimic a fully support condition. The flow deviation at the mitral valve, the blood low-velocity volume as well as the residence time and shear stress history of the particles were calculated. Inclusion of the LA deflects the flow at the mitral valve by 25°, resulting in an asymmetric flow jet entering the left ventricle. This reduced the ventricular low-velocity volume by 40% (from 6.4 to 3.9 cm3), increased (40%) the shear stress experienced by particles and correspondingly increased (27%) their residence time. Under the studied conditions, the atrial geometry plays a major role in the development of intraventricular flow patterns. A reliable prediction of blood flow dynamics and consequently thrombosis risk analysis within the ventricle requires the consideration of the LA in computational simulations.


Assuntos
Coração Auxiliar , Modelos Cardiovasculares , Velocidade do Fluxo Sanguíneo , Simulação por Computador , Átrios do Coração , Ventrículos do Coração/diagnóstico por imagem , Hemodinâmica/fisiologia
15.
Eur J Cardiothorac Surg ; 61(3): 716-724, 2022 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-34468714

RESUMO

OBJECTIVES: We reviewed our institutional experience with outflow graft stenosis (OGS) in 3 contemporary left ventricular assist devices (LVAD). METHODS: Data from 347 consecutive adult recipients of LVAD [Medtronic HVAD (n = 184, 53.0%), Abbott HeartMate II (n = 62, 17.9%) and Abbott HeartMate 3 (n = 101, 29.1%)] implanted between March 2006 and October 2019 were analysed retrospectively. Primary study end points were the incidence of OGS necessitating treatment and survival on LVAD support. RESULTS: During the study period, 17 patients (4.9%) developed OGS requiring treatment with a probability of 0.6% at 1 year, 1.9% at 2 years, 3.8% at 3 years, 4.7% at 4 years and 5.9% at 5 years of LVAD support. Notably, in 13.8% of patients, a compression-related narrowing of the outflow graft with a probability of 1.5% at 6 months, 1.8% 1 year, 6.0% at 2 years, 12.3% at 3 years, 15.4% at 4 years and 16.6% at 5 years of LVAD support with no difference between devices (P = 0.26) was observed. There was a trend towards increased risk of mortality with OGS (hazard ratio 2.21, 95% confidence interval 0.87-5.51; P = 0.09). OGS preferentially occurred in segments of the outflow graft covered by a protective coating. CONCLUSIONS: OGS is a rare but potentially lethal complication during LVAD support. Modifications of pump design and implant techniques may be needed because OGS preferentially occurs within covered portions of the outflow graft. Systematic screening may be warranted.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Adulto , Constrição Patológica/etiologia , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Incidência , Estudos Retrospectivos
16.
Acta Biomater ; 134: 276-288, 2021 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-34329787

RESUMO

Currently available synthetic small diameter vascular grafts reveal low patency rates due to thrombosis and intimal hyperplasia. Biofunctionalized grafts releasing nitric oxide (NO) in situ may overcome these limitations. In this study, a drug-eluting vascular graft was designed by blending polycaprolactone (PCL) with S-nitroso-human-serum-albumin (S-NO-HSA), a nitric oxide donor with prolonged half-life. PCL-S-NO-HSA grafts and patches were fabricated via electrospinning. The fabrication process was optimized. Patches were characterized in vitro for their morphology, drug release, biomechanics, inflammatory effects, cell proliferation, and expression of adhesion molecules. The selected optimized formulation (8%PCL-S-NO-HSA) had superior mechanical/morphological properties with high protein content revealing extended NO release (for 28 days). 8%PCL-S-NO-HSA patches significantly promoted endothelial cell proliferation while limiting smooth muscle cell proliferation. Expression of adhesion molecules (ICAM-1, VCAM-1) and pro-inflammatory macrophage/cytokine markers (CD80, IL-1α, TNF-α) was significantly reduced. 8%PCL-S-NO-HSA patches had superior immunomodulatory properties by up-regulating anti-inflammatory cytokines (IL-10) and M2 macrophage marker (CD163) at final time points. Grafts were further evaluated in a small rodent model as aortic implants up to 12 weeks. Grafts were assessed by magnetic resonance imaging angiography (MRI) in vivo and after retrieval by histology. All grafts remained 100 % patent with no signs of thrombosis or calcification. 8%PCL-S-NO-HSA vascular grafts supported rapid endothelialization, whereas smooth muscle cell proliferation was hampered in earlier phases. This study indicates that 8%PCL-S-NO-HSA grafts effectively support long-term in situ release of bioactive NO. The beneficial effects observed can be promising features for long-term success of small diameter vascular grafts. STATEMENT OF SIGNIFICANCE: Despite extensive research in the field of small diameter vascular graft replacement, there is still no appropriate substitute to autografts yet. Various limitations are associated with currently available synthetic vascular grafts such as thrombogenicity and intimal hyperplasia. Therefore, developing new generations of such conduits has become a major focus of research. One of the most significant signaling molecules that are involved in homeostasis of the vascular system is nitric oxide. The new designed nitric-oxide eluting vascular grafts described in this study induce rapid surface endothelialization and late migration of SMCs into the graft wall. These beneficial effects have potential to improve current limitations of small diameter vascular grafts.


Assuntos
Preparações Farmacêuticas , Enxerto Vascular , Prótese Vascular , Doadores de Óxido Nítrico , Poliésteres , Albumina Sérica Humana
17.
Int J Artif Organs ; 44(12): 956-964, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34088235

RESUMO

Malpositioning of left ventricular assist devices (LVAD) is a risk factor for thrombosis, but its identification from clinical imaging remains challenging. X-rays and CT scans were analyzed and parameters identified that correlated to pump thrombosis. Retrospective imaging data of patients (n = 115) with HeartmateII (HMII) or HVAD were analyzed in two groups (pump-thrombosis PT, n = 15 vs matched control group NT, n = 15) using routine X-rays and CT scans. In CT, directional deviations of the inflow cannula in three-chamber and two-chamber view (α and ß angles) were identified. In HVAD PT frontal radiographs showed reduced pump body area and smaller minor axis (PT 41.3 ± 4.8 mm vs NT 34.9 ± 6.0 mm, p = 0.026), and in the lateral radiographs the visibility of the inflow cannula served as a predictive parameter for PT. In HMII patients, no parameters were associated with PT. The angle α differed significantly (NT -1.2 ± 7.5°, PT -22.0 ± 4.7°, p = 0.006) in HVAD patients. Further, correlations of x-ray parameters with CT angles α and ß showed that radiographs can be used to identify malpositioned pumps. Well-aligned inflow cannula positions are essential. HVAD patients with a posterior rotation of the inflow cannula have a higher risk of pump thrombosis. This risk can reliably be identified from routine radiographs.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Trombose , Ventrículos do Coração , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Trombose/diagnóstico por imagem , Trombose/etiologia , Tomografia Computadorizada por Raios X
18.
Mater Sci Eng C Mater Biol Appl ; 124: 112085, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33947575

RESUMO

Conventional electrospun small diameter vascular grafts have a random fiber orientation. In order to achieve mechanical characteristics similar to a native blood vessel, a controllable fiber orientation is of interest. In this study the electrospinning jet was directly controlled by means of an auxiliary, changeable electrostatic field, so that the fibers could be deposited in adjustable orientations. Prostheses with circumferentially, axially, fenestrated and randomly aligned fibers were electrospun on Ø2mm mandrels out of a thermoplastic polyurethane (PUR) and a polylactid acid (PLLA). The impact of the materials and the various preferential fiber orientations on the resulting biomechanics was investigated and compared with that of the native rat aorta in quasistatic and dynamic hoop tensile tests. The test protocol included 3000 dynamic loading cycles in the physiological blood pressure range and ended with a quasistatic tensile test. Any orientation of the fibers in a particular direction resulted in a significant reduction in scaffold porosity for both materials. The standard randomly oriented PUR grafts showed the highest compliance of 29.7 ± 5.5 [%/100 mmHg] and were thus closest to the compliance of the rat aortas, which was 37.2 ± 6.5 [%/100 mmHg]. The maximum tensile force was increased at least 6 times compared to randomly spun grafts by orienting the fibers in the circumferential direction. During the 3000 loading cycles, creeping of the native rat aorta was below 1% whereas the electrospun grafts showed creeping up to 2.4 ± 1.2%. Although the preferred fiber orientations were only partially visible in the scanning electron micrographs, the mechanical effects were evident. The investigations suggest a multi-layer wall structure of the vascular prosthesis, since none of the preferred fiber directions and the materials used could imitate the typical j-shaped mechanical characteristics of the rat aorta.


Assuntos
Prótese Vascular , Enxerto Vascular , Animais , Aorta , Fenômenos Mecânicos , Poliuretanos , Ratos
19.
Ann Cardiothorac Surg ; 10(2): 221-232, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33842216

RESUMO

Technological progress of left ventricular assist devices (LVADs) towards rotary blood pumps and the optimization of medical management contributed to the significant improvements in patient survival as well as LVAD support duration. Even though LVAD therapy is now well-established for end-stage heart failure patients, the long-term occurrence of adverse events (AE) such as bleeding, infection or stroke, still represent a relevant burden. An early detection of AE, before onset of major symptoms, can lead to further optimization of patient treatment and thus mitigate the burden of AE. Continuous patient monitoring facilitates identification of pathophysiological states and allows anticipation of AE to improve patient management. In this paper, methods, algorithms and possibilities for continuous patient monitoring based on LVAD data are reviewed. While experience with continuous LVAD monitoring is currently limited to a few centers worldwide, the pace of developments in this field is fast and we expect these technologies to have a global impact on the well-being of LVAD patients.

20.
ASAIO J ; 67(5): 517-528, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33606388

RESUMO

Left ventricular assist devices inherently alter the intraventricular flow field and create areas of blood stasis with potential thrombus formation. The Lavare cycle of the Medtronic HeartWare HVAD was designed to improve ventricular washout. This study aims to evaluate its effects on ventricular washout in a pulsatile in vitro setting with a focus on the timing of pump speed changes. Ventricular flow fields were obtained via particle image velocimetry in two modes: With constant left ventricular assist devices speed and with the Lavare cycle applied. The start of the Lavare cycle was shifted over an entire cardiac cycle, and ventricular washout was evaluated based on velocity fields, kinetic energy, and normalized pulsatility of flow fields. The ventricular flow fields showed dependence on the timing of the Lavare cycle and interaction between speed changes and the cardiac phase. Higher apical velocity was observed for speed decreases at the late E wave and for increases at mid systole by 29% (P = 0.002) and 61% (P < 0.001), respectively. Mean apical kinetic energy for these phases also increased by 21% (P = 0.0013) and 46% (P < 0.001). The Lavare cycle generally promotes higher apical washout and can specifically generate further improved washout if speed steps are applied at the correct timing on the cardiac cycle.


Assuntos
Coração Auxiliar , Ventrículos do Coração/fisiopatologia , Humanos , Fluxo Pulsátil , Reologia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS